NIBP Accuracy Validation in Adults
Official title: Non-Invasive Blood Pressure Accuracy Study for Adult Subject Populations
Run by GE Healthcare · NCT07697950 · Data updated 2026-11-12
This study tests how accurately a non-invasive blood pressure device measures blood pressure in adults by comparing it with arterial line readings.
Quick facts
| Study type | Interventional |
|---|---|
| Ages | 18 Years and up |
| Sex | All |
| Enrollment | 130 (estimated) |
| Sponsor | GE Healthcare Industry-sponsored |
| Locations | 1 site (Helsinki) |
| Status | Recruiting |
| Started | January 13, 2025 |
| Main results expected | December 31, 2026 |
| Study ends | December 31, 2027 |
| Registry record updated | July 13, 2026 |
| Trial ID | NCT07697950 on ClinicalTrials.gov |
Is this trial a fit for you?
✓Likely a good fit
Adults aged 18 and older who have an arterial line and cuff-fit appropriate limbs, and can consent and remain in the unit for the procedure.
✕Probably not a fit
Patients without an arterial line or unsuitable cuff fit, or those who do not meet other inclusion criteria, may not benefit.
A plain-English reading of the study's rules. Only the study team can confirm whether you qualify.
What this trial studies
This interventional study collects non-invasive blood pressure data alongside invasive aortic pressure measurements to validate NIBP measurement algorithms. It follows IEC 80601-2-30:2018 and ISO 81060-2:2018+AMD2:2024 standards for clinical validation. Eligible participants are adults with suitable cuff sizes and an arterial line in place, excluding those with certain conditions or previous participation. Data will be gathered in a hospital setting to assess accuracy and performance of the NIBP standard parameter module. Lead sponsor is GE Healthcare, with the study conducted at Tower Hospital and the Heart and Lung Center in Helsinki.
Why it matters
Potential benefit: If successful, the study could improve confidence in cuff-based blood pressure measurements and support deployment of more accurate NIBP devices.
How similar studies have gone: Previous validation studies have demonstrated feasibility of validating NIBP devices against invasive measurements, though results may vary by device and population.
Who can join: the full rules
Show full inclusion / exclusion criteria
Inclusion Criteria: 1. Age requirement: 18 and over. 2. Have an upper limb (right OR left side) that fits the cuff size of the device (circumference ranging 17 cm to 40 cm) OR have a thigh (right OR left side) that fits a cuff size of the device (circumference ranging 38 to 50 cm). 3. Have an arterial line as a standard of care, which measures blood pressure at the aortic root. 4. Able to provide written informed consent. 5. Expected to remain in the unit for the duration of the study procedure. Exclusion Criteria: 1. Have previously participated in this study (no subject may participate more than once). 2. Pregnant and lactating women per site standard of care. 3. Subjects with peripheral arterial diseases (causing left/right arm difference) 4. Hemodynamically unstable subjects at the discretion of the investigator. 5. Exhibited injuries, deformities, intravenous lines, or other abnormalities that, in the opinion of the Investigator, may prevent proper cuff application or functioning. 6. Are suffering from infection(s) or immunocompromised patients that require isolation. 7. PI or designee decision due to subject health conditions
Where it's running
-
Tower Hospital, the Heart and Lung Center
Helsinki, Finland Recruiting
Study contacts
- Study coordinator: Pasi Karjalainen
- Email: pasi.karjalainen@hus.fi
- Phone: + 358 40 5480853
Similar studies
Other studies for the same condition or treatment. Recruiting studies are listed first.
-
Automated Non-Invasive Blood Pressure: Tracking Blood Pressure Changes Using SpO2 Data
This study tests an algorithm that estimates blood pressure changes using data from an SpO2 sensor in patients in the OR, PACU, or ICU who already have invasive BP measured as part of standard care.
-
New Non-Invasive Blood Pressure (NIBP) Enhancement for Neonates and Children
This study tests a new NIBP device enhancement in neonates and kids to see if it can measure blood pressure more accurately.
-
Non-invasive blood pressure accuracy study for adults
This study tests whether non-invasive blood pressure readings match invasive aortic pressure measurements in adults who need arterial line monitoring.
-
Inflation-based non-invasive blood pressure test compared with standard cuff method
This study tests whether the Philips iNIBP device gives BP readings that match the usual auscultatory cuff method in people aged 3 to 85.
-
Overnight Temperature Regulation to Test Gut Health, Inflammation, and Circadian Rhythms
This study tests whether two weeks of using the Eight Sleep Pod at night can improve gut bacteria balance, lower inflammation, and strengthen daily temperature and blood pressure rhythms in postmenopausal women and age-matched men with poor sleep.
-
Blood Pressure from Face Video (Vitacam)
A contactless vitals tool called Vitacam tests if video-based blood pressure readings from the face can match standard cuff measurements in adults.
How to take part
- Review the eligibility criteria above with your treating physician.
- Check the official listing on ClinicalTrials.gov for the latest contact details and recruitment status.
- Contact the study coordinator or principal investigator to ask for pre-screening. Pre-screening is free and never obligates you to enroll.