Heli-FX EndoAnchor system in abdominal aortic aneurysm patients in China
Official title: Aneurysm Treatment Using the Heli-FX™ EndoAnchor™ System China Study(ATHENA)
Run by Medtronic Cardiovascular · NCT07754318 · Data updated 2026-11-12
This study tests whether the Heli-FX EndoAnchor device can safely and effectively help seal and fix AAA patients at high risk of endoleaks or migration after repair.
Quick facts
| Study type | Interventional |
|---|---|
| Ages | 18 Years and up |
| Sex | All |
| Enrollment | 142 (estimated) |
| Sponsor | Medtronic Cardiovascular Industry-sponsored |
| Locations | 1 site (Beijing) |
| Status | Recruiting |
| Started | August 26, 2026 |
| Main results expected | August 2028 |
| Study ends | August 2030 |
| Registry record updated | September 14, 2026 |
| Trial ID | NCT07754318 on ClinicalTrials.gov |
Is this trial a fit for you?
✓Likely a good fit
Adults with AAA meeting defined neck and iliac measurements and high-risk anatomy who consent to participate.
✕Probably not a fit
Patients not meeting the anatomical criteria or who do not experience improved fixation or sealing may not benefit.
A plain-English reading of the study's rules. Only the study team can confirm whether you qualify.
What this trial studies
This interventional study evaluates the safety and effectiveness of the Heli-FX EndoAnchor system in adults with abdominal aortic aneurysm who are at high risk of endoleaks or aneurysm-related complications after repair. Eligible participants have specific aneurysm neck dimensions and iliac features, and must meet high-risk anatomical criteria. The goal is to support regulatory registration with the NMPA in China by demonstrating device performance in augmented radial fixation and sealing. The study is conducted at Beijing Anzhen Hospital with Medtronic Cardiovascular as lead sponsor.
Why it matters
Potential benefit: If successful, patients may experience improved sealing of the aneurysm repair and reduced risk of endoleaks or device migration.
How similar studies have gone: Previous studies of endoanchors in AAA have shown potential for improved fixation and reduced endoleak risk, though results vary by population and device placement.
Who can join: the full rules
Show full inclusion / exclusion criteria
Inclusion Criteria: * Aged 18 years or older; * Male or non-pregnant female patients; women of childbearing potential must undergo a pregnancy test prior to enrollment, and the result must be negative; * Willing and able to provide written informed consent; * Maximum diameter of the abdominal aortic aneurysm (AAA) ≥ 4.5 cm in females or ≥ 5 cm in males; * Proximal neck diameter of the AAA ranging from 19 to 32 mm; * Distal fixation zone length of both iliac arteries ≥ 15 mm; * Diameter of iliac artery fixation zones on both sides ranging from 8 to 25 mm; * ≤ 60° infrarenal and ≤ 45°suprarenal angulation OR ≤ 75°infrarenal and ≤ 60°suprarenal angulation with proximal necks ≥ 15 mm in length; * Presence of high-risk anatomical criteria, defined as meeting any one of the following criteria: 1. Proximal neck diameter \> 28 mm and ≤ 32mm 2. Proximal neck length ≥ 10 mm and \< 15 mm 3. Neck angulation ≥ 60°and ≤ 75° (angle between the long axis of the proximal neck and the long axis of the aneurysm sac) 4. Conical neck (defined as diameter increased \> 10% compared with the immediate infrarenal diameter over the first 10 mm beyond the lowest main renal artery) 5. Investigator determined subject could benefit from this Heli-FX procedure * Patients deemed by the investigator to be suitable candidates for elective AAA repair; * Patients who agree to return to the treating investigator for all scheduled follow-up visits and are able to attend hospital-based follow-up; * Life expectancy \> 2 years Exclusion Criteria: * Myocardial infarction within the past 3 months; * Systemic infection; * Ruptured or leaking AAA; * Infected or inflammatory AAA; * Known hereditary connective tissue disorders (e.g., Marfan syndrome or Ehlers-Danlos syndrome); * Concomitant thoracic aortic aneurysm or thoracoabdominal aortic aneurysm; * Requirement for emergency AAA repair; * History of prior AAA repair; * Patient body habitus that interferes with required imaging studies; * In the opinion of the investigator, the patient has serious comorbidities that may pose an unacceptable risk for general anesthesia or endovascular intervention; * Planned major surgery (e.g., thoracic aorta, renal, superior mesenteric artery/celiac or lower extremity revascularization, IMA reimplantation, permanent vascular access, cholecystectomy) concurrent with or within 30 days before or after the AAA repair procedure; * Renal failure requiring dialysis; * Patient has a known hypersensitivity or contraindication to anticoagulants, anti-platelets, or contrast media, which is not amenable to pre-treatment; * Known hypersensitivity or allergy to polyester, nickel, titanium, tantalum, chromium, molybdenum, and/or cobalt; * Patients who cannot discontinue oral anticoagulation or antiplatelet therapy at the time of the study procedure; * Bleeding diathesis or hypercoagulable state; * Sealing zone thrombus, calcium or plaque \> 2 mm in thickness or covering \> 50% (180 degrees) of the vessel circumference; * Irregularly shaped calcification and/or plaques at the proximal implantation sites that may interfere with proper deployment of the EndoAnchor implants; * Mental disorders or other conditions that may impair the patient's ability to understand the nature, significance, and/or scope of the study; * Participation in another investigational drug or device trial without having completed the required follow-up. * Endograft planned to be used had not undergone in vitro evaluation to confirm its compatibility with the EndoAnchor implant and the aortic fixation system.
Where it's running
-
Beijing Anzhen Hospital Capital Medical University
Beijing, China Recruiting
Study contacts
- Study coordinator: Fairy Liu
- Email: fairy.liu@medtronic.com
- Phone: 86-021-20325765
Similar studies
Other studies for the same condition or treatment. Recruiting studies are listed first.
-
TUVA BX and iCover stent grafts used in BEVAR for complex aortic aneurysms
This study looks at whether the TUVA BX and iCover stent grafts used during BEVAR procedures are safe and perform well in real-world patients with complex abdominal or thoracoabdominal aneurysms.
-
Retreatment with the Nectero EAST System for abdominal aortic aneurysm
This will try retreatment with the Nectero EAST System to repair infrarenal abdominal aortic aneurysms in adults who previously received the device under the initial protocol.
-
Abdominal CT offered alongside lung screening for people who have smoked
We will test whether mentioning a possible extra abdominal CT in the lung screening invitation changes whether people aged 55–70 who have ever smoked attend their lung screening appointment.
-
Observational registry for patients treated with GORE® endovascular devices for abdominal aortic aneurysms
This study is tracking patients who have been treated with GORE® devices for abdominal aortic aneurysms to see how they do over the next 10 years.
-
Evaluating outcomes of endovascular abdominal aortic aneurysm repair
This study is testing two different devices for repairing abdominal aortic aneurysms to see which one works better for patients over time.
-
Using Aortoseal to improve AAA endovascular graft procedures
This study is testing a new device called Aortoseal to see if it can help improve the way doctors attach grafts during surgery for people with abdominal aortic aneurysms.
How to take part
- Review the eligibility criteria above with your treating physician.
- Check the official listing on ClinicalTrials.gov for the latest contact details and recruitment status.
- Contact the study coordinator or principal investigator to ask for pre-screening. Pre-screening is free and never obligates you to enroll.