Repairing complex aortic aneurysms with a specialized stent-graft
Official title: Clinical Outcomes and Quality of Life Measures in Patients Treated for Complex Abdominal, Thoracoabdominal and Aortic Arch Aneurysms or Dissections With Fenestrated and Branched Stent Grafts
Run by Baylor College of Medicine · NCT02089607 · Data updated 2026-11-12
This study is testing a special stent-graft to see if it safely and effectively repairs complex aortic aneurysms in patients who have them.
Quick facts
| Study type | Interventional |
|---|---|
| Ages | 18 Years and up |
| Sex | All |
| Enrollment | 760 (estimated) |
| Sponsor | Baylor College of Medicine Academic / other |
| Drugs / interventions | radiation |
| Locations | 3 sites (Rochester, Minnesota and 2 other locations) |
| Status | Recruiting |
| Started | March 2014 |
| Main results expected | March 2028 |
| Study ends | May 2032 |
| Registry record updated | August 27, 2026 |
| Trial ID | NCT02089607 on ClinicalTrials.gov |
Is this trial a fit for you?
✓Likely a good fit
Ideal candidates are adults with thoracoabdominal or aortic arch aneurysms that meet specific size and growth criteria.
✕Probably not a fit
Patients under 18 years old, those with a life expectancy of less than 2 years, or those who have had recent surgical interventions may not benefit from this study.
A plain-English reading of the study's rules. Only the study team can confirm whether you qualify.
What this trial studies
This study aims to evaluate the safety and effectiveness of the Zenith t-Branch and customized physician-specified stent-graft for repairing complex aortic aneurysms. It involves a traditional device feasibility approach to gather preliminary data that could inform future studies or product development. The procedure utilizes endovascular techniques to insert a graft through the groin arteries, which includes fenestrations or branches to maintain blood flow to vital organs. Patients diagnosed with significant aortic aneurysms will be monitored for outcomes related to the graft's performance.
Why it matters
Potential benefit: If successful, this approach could significantly reduce the risk of rupture and improve outcomes for patients with complex aortic aneurysms.
How similar studies have gone: Other studies have shown promise with similar endovascular approaches, indicating potential for success in this novel application.
Who can join: the full rules
Show full inclusion / exclusion criteria
General Inclusion Criteria: * Thoracoabdominal aortic aneurysm with a diameter ≥ 5.5 cm or 2 times the normal aortic diameter. * Aneurysm with a history of growth ≥ 0.5 cm per year. * Saccular aneurysms deemed at significant risk for rupture based upon physician interpretation. * Presence of concomitant thoracoabdominal and aortic arch aneurysm meeting one of the above-mentioned criteria. * Presence of thoracoabdominal aortic aneurysm meeting one of the above-mentioned criteria with unilateral or bilateral common iliac artery aneurysm with diameter ≥ 3.0-cm or saccular morphology with no suitable landing zone proximal to iliac bifurcation. General Exclusion Criteria: * Less than 18 years of age * Unwilling to comply with the follow-up schedule * Inability or refusal to give informed consent by the patient or a legally authorized representative * Pregnant or breastfeeding * Life expectancy \< 2 years * Prior open surgical or interventional procedure within 30 days of the anticipated date of the fenestrated-branched procedure, with the exception of planned staged procedures to provide access for repair (e.g. staged iliac conduit, cervical debranching, elephant trunk repair), to facilitate the procedure by allowing open revascularization of a target artery not amenable to revascularization with the investigational device, such as an internal iliac artery, subclavian artery or visceral artery with early bifurcation, tortuosity or occlusive disease preventing successful placement of alignment side stents. * Participation in another investigational clinical or device trial, with the exception of participation in another investigational endovascular stent-graft protocol, percutaneous aortic valve protocol, or concomitant clinical trials designed to evaluate medical therapy strategies to reduce perioperative risk during fenestrated-branched endovascular repair, including risks of renal dysfunction, contrast-induced nephropathy, neurologic, spinal cord or cardiac complications, and/or use of advanced imaging to reduce radiation exposure during implantation of these devices. Participation in investigational device trials not encompassed by the IDE protocol should be performed remotely from the fenestrated procedure (\> 30 days). Examples include remote (\>30 days) participation in a thoracic, abdominal or iliac branch device trial, or participation in a percutaneous aortic valve trial. Participation in medical therapy trial or advanced imaging trial designed to improve peri-operative outcomes or to reduce radiation exposure of fenestrated-branched endografts may be concurrent with the IDE study. Examples include therapy directed to reduce rates of spinal cord injury, stroke and contrast-induced nephropathy associated with implantation of fenestrated-branched stent-grafts or advanced imaging trials designed to reduce radiation exposure during repair. * Patients with ruptured aortic aneurysms requiring urgent or emergent repair, with the exception of patients with contained, stable ruptures with anatomy suitable for an off-the-shelf design. Medical Exclusion Criteria: * Known sensitivities or allergies to stainless steel, nitinol, polyester, solder (tin, silver), polypropylene, PTFE, urethane or gold * History of anaphylactic reaction to contrast material that cannot be adequately pre-medicated * Leaking or ruptured aneurysm associated with hypotension * Uncorrectable coagulopathy * Mycotic aneurysm or patients with evidence of active systemic infection. * History of connective tissue disorder (e.g vascular Ehlers Danlos, Marfans syndrome), with the exception of those patients who had prior open surgical aortic replacement, where a surgical graft would serve as landing zone for the investigational stent-graft, those who are deemed prohibitive risk for open surgical repair or connective tissue disorders with no effect of vascular system (e.g non-vascular forms of Ehlers Danlos). * Body habitus that would inhibit X-ray visualization of the aorta and its branches. Anatomical Exclusion Criteria: * Inadequate femoral or iliac access compatible with the required delivery systems. * Inability to perform a temporary or permanent open surgical or endovascular iliac conduit for patients with inadequate femoral/iliac access. * Absence of a non-aneurysmal aortic segment in the distal thoracic aorta above the diaphragmatic hiatus with: a. A diameter measured outer wall to outer wall of no greater than 42mm and no less than 21 mm; b. Parallel aortic wall with \<20% diameter change and without significant calcification and/or thrombus in the selected area of seal zone * Visceral vessel anatomy not compatible with Zenith t-Branch or patient-specific stent-graft due to excessive occlusive disease or small size not amenable to stent graft placement * Unsuitable distal iliac artery fixation site and anatomy for iliac limb extension or iliac branch device: a. Common iliac artery fixation site diameter, measured outer wall to outer wall on a sectional image (CT) \<8.0 mm with inability to perform open surgical conduit ; b. Iliac artery diameter, measured outer wall to outer wall on a sectional image (CT) \>20 mm at distal fixation site, with inability to perform open internal iliac artery revascularization or iliac branch stent graft ; c. Non-aneurysmal external liac artery distal fixation site \<10 mm in length ; d. Non-aneurysmal internal iliac artery main trunk or branch segment with length \<10mm or with inner wall diameter \<4 or \>14mm; e. Unsuitable anatomy due to inability to preserve at least one hypogastric artery Additional anatomical inclusion criteria for aortic arch devices: * Proximal aortic fixation zone: a. Native aorta or surgical graft; b. Diameter: 20-42mm; c. Proximal neck length ≥ 20mm; d. Ascending aortic length ≥50mm; e. Must occur distal to coronary arteries and any coronary artery bypass grafts that are considered patent and necessary for proper cardiac perfusion * Distal aortic fixation zone:; a. Native aorta or surgical graft; b. Diameter: 20-42mm; c. Distal neck length ≥20mm * Supra-aortic trunk (brachiocephalic) vessels: a. Although the prosthesis will typically have two branches, modifications to the design will allow for a single branch, three branches or combination of branch and scallop if a customized version is required. Thus, it is generally planned that at least one extra-anatomic bypass graft will be done in conjunction (or in a staged fashion) with the procedure, unless three branches are planned. The two vessels incorporated into the endograft repair would most commonly be the innominate artery and left common carotid artery. However, the innominate artery may be coupled with the left subclavian artery in the setting of a bovine arch whereby the flow to the left carotid would come from a left subclavian to carotid bypass. Similarly, the left carotid and subclavian artery may be branched, or simply one vessel branched should specific anatomic limitations exist. In such a situation, multiple extra-anatomic bypasses may be necessary. A design with a single subclavian retrograde branch and double scallop to the left carotid artery may be used to extent the landing zone to Zone 1. Finally, a design with two antegrade inner branches for the innominate and left common carotid, and one retrograde inner branch for the left subclavian artery may be used in select cases. Thus the inclusion criteria are defined for each artery, yet any combination of arteries may be used for a repair: Innominate artery (Native vessel or surgical graft, Diameter: 8-22mm, Length of sealing zone ≥10mm, Acceptable tortuosity); Left (or right) common carotid artery (Native vessel or surgical graft, Diameter 6-16mm, Length of sealing zone ≥10mm, Acceptable tortuosity); Left (or right) common carotid artery (Native vessel or surgical graft, Diameter: 5-20mm, Length of sealing zone ≥10mm, Acceptable tortuosity). * In the setting of an aortic dissection the following criteria must exist: a. Access into the true lumen from the groin and at least one supra-aortic trunk vessel; b. A sealing zone in the target aorta (or surgical graft) that is proximal to the primary dissection, such that a stent-graft would be anticipated to seal off the dissection lumen; c. A sealing zone in the target supra-aortic trunk vessels that is distal to the dissection, anticipated to seal off the dissection lumen, or surgically created; d. A true lumen size large enough to deploy the device and still gain access into the target branches * In the setting of more distal disease: a. The repair may be coupled with a thoracoabdominal branched device, infrarenal device, and/or internal iliac branch device. * Iliac anatomy must allow for the delivery of the arch branch device which is loaded within a 20F-24F sheath. Thus the iliac requirements are no different than the standard thoracic protocol. Conduits to the iliac vessels or aorta may be used if deemed necessary.
Where it's running
-
Baylor College of Medicine
Houston, Texas, United States Recruiting -
Mayo Clinic
Rochester, Minnesota, United States Active not recruiting -
University of Texas Health Science Center at Houston
Houston, Texas, United States Active not recruiting
Study contacts
- Principal investigator: Gustavo S. Oderich, MD — Baylor College of Medicine
- Study coordinator: Andrea C Martinez, BS
- Email: andrea.martinez@bcm.edu
- Phone: 713-798-6835
Similar studies
Other studies for the same condition or treatment. Recruiting studies are listed first.
-
Collecting data on custom-made stent-graft devices for aortic treatment
This study is testing how safe and effective custom-made stent-grafts are for treating complex aortic conditions in real-world settings.
-
GORE TBE Device in Zone 0/1 for Aortic Arch Conditions
This study tests the GORE TAG Thoracic Branch Endoprosthesis in adults with aortic arch problems in Zone 0 or 1 to see how it performs over several years in routine care.
-
Arcevo LSA stent graft for repairing aortic arch dissections and aneurysms
This trial will test whether the Arcevo LSA stent graft can safely and effectively repair aortic arch and descending thoracic aortic dissections or aneurysms in adults.
-
Modified endograft treatment for complex aortic aneurysms
This study is testing a special type of stent to see if it can safely treat complex aortic aneurysms in high-risk patients who can’t use regular devices.
-
Evaluating new endografts for treating complex aortic conditions
This study is testing new types of stents for people with complicated aortic conditions to see if they are safe and effective compared to standard treatments.
-
Evaluating new endografts for treating aortic aneurysms
This study is testing two new types of stent-grafts to see if they can safely and effectively treat aortic aneurysms in patients who can't use standard treatments.
How to take part
- Review the eligibility criteria above with your treating physician.
- Check the official listing on ClinicalTrials.gov for the latest contact details and recruitment status.
- Contact the study coordinator or principal investigator to ask for pre-screening. Pre-screening is free and never obligates you to enroll.