First-in-human flow-based heart support device for advanced heart failure
Official title: A Prospective, Single Arm, Multicentric, First in Human Study to Evaluate the Safety and Performance at 30 Days of the FineHeart Icoms® FlowMaker® in Subjects With Advanced Heart Failure.
Run by FineHeart · NCT07632586 · Data updated 2026-11-12
A first-in-human trial is testing the Icoms FlowMaker, a wireless implantable heart assist device, in adults with advanced heart failure who are at high risk for traditional LVAD or driveline options.
Quick facts
| Study type | Interventional |
|---|---|
| Ages | 18 Years to 80 Years |
| Sex | All |
| Enrollment | 10 (estimated) |
| Sponsor | FineHeart Industry-sponsored |
| Locations | 2 sites (Prague and 1 other locations) |
| Status | Recruiting |
| Started | December 19, 2023 |
| Main results expected | December 2027 |
| Study ends | December 2029 |
| Registry record updated | June 8, 2026 |
| Trial ID | NCT07632586 on ClinicalTrials.gov |
Is this trial a fit for you?
✓Likely a good fit
Adults 18–80 with advanced heart failure, reduced ejection fraction (LVEF ≤ 35%), Intermacs ≤ 4, adequate body size (BSA ≥ 1.2 m²), and suitable anatomy, who are at high risk for conventional LVAD/driveline and meet consent and safety criteria.
✕Probably not a fit
Patients without advanced heart failure, with unsuitable anatomy or medical comorbidities, or who do not meet the device-specific criteria may not benefit.
A plain-English reading of the study's rules. Only the study team can confirm whether you qualify.
What this trial studies
This first-in-human study will implant the Icoms FlowMaker in up to ten adults with severe heart failure across sites in France, Slovenia, and the Czech Republic. The trial aims to assess safety and device performance when added to the heart’s native pumping action. Participants must meet specific anatomical and functional criteria and provide informed consent. The study is conducted under investigator-selected criteria to identify patients for whom conventional LVAD is high-risk or unsuitable.
Why it matters
Potential benefit: If successful, the FlowMaker could provide additional blood flow support for patients who cannot undergo standard LVAD implantation.
How similar studies have gone: This is an initial human test; prior devices and flows have shown promise in theory, but direct human data for this exact flowmaker is limited.
Who can join: the full rules
Show full inclusion / exclusion criteria
Inclusion Criteria: * 1- Age 18 and 80 years included. * 2- Written inform consent. * 3- Females of child-bearing age must agree to use adequate contraception. * 4- Suitable neurocognitive status. * 5- Distance between the aortic valve and the LV endocardial apex ≥ 95mm and the Left Ventricular (LV) volume \> 200 mL * 6- Body Surface Area (BSA) ≥ 1.2 m². * 7- LVEF ≤ 35 % and assessed Intermacs ≤ 4 * 8- Advanced heart failure patients symptomatic despite optimal medical management (OMM) based on the European Cardiology Society guidelines15 otherwise meeting standard best practice indications for implantable LVAD AND fulfilling at least one of the following criteria approved by the International multidisciplinary expert selection committee: • 9- Contraindication or excessively heightened risk of a conventional LVAD implant due to factors such as: * CVP/PCWP ≤ 0.6 * anatomical or surgical factors constituting excessive * perioperative implant risks. * (Duly recorded in the source document during the patient Inform * consent process) OR * 10- Patient with high risk of percutaneous driveline-induced morbidity such as: * patient with recurrent infections / severe diabetes mellitus / immunodeficiency / cachexia * psychological factors limiting percutaneous driveline * acceptance and / or management duly recorded in the Psychological evaluation report at screening. * 11- Temporary ineligibility to heart transplant(active or remission of cancer / highly sensitized PRA…) Duly recorded in the source document during the patient Inform consent process. * 12- Patient's affiliation to health care insurance, if local requirement * 13- Patient implanted with a cardioverter defibrillator from Medtronic and Boston or patient requiring implantation of a cardiac defibrillator due to a risk of ventricular arrhythmia Exclusion Criteria: * 1-Body Mass Index (BMI) \> 40. * 2- TAPSE ≤10 mm * 3- Pulmonary VTI ≤ 6cm * 4- Patients not eligible to transplant due to surgical risks * 5- Existence of any ongoing mechanical circulatory support (MCS) other than an intra-aortic balloon pump (IABP) * 6- History of left thoracotomy. * 7- History of confirmed untreated abdominal or thoracic aortic aneurysm \> 5 cm. * 8- Cardiothoracic surgery within 30 days of implant. * 9- Acute myocardial infarction within 14 days of implant. * 10- On ventilator support for \> 72 hours within the four days immediately prior to implant. * 11- Pulmonary embolus within three weeks of implant. * 12- Presence of current atrial or ventricular thrombus, confirmed by MRI, CT-SCAN or Trans-Esophageal Echocardiography. * 13- Symptomatic cerebrovascular disease, stroke within 180 days of screening or \> 80% stenosis of carotid, vertebral or cranial vessels. * 14- Moderate to severe aortic regurgitation, defined as \> 50% regurgitant fraction. * 15- Moderate - Severe aortic stenosis, defined as an aortic valve area (AVA) ≤ 1.5 cm2. * 16- Active, uncontrolled infections, history of hyperleukocytosis with Leucocytes \> 10.000/mm3, CRP 17- 10mg/l, PCT \> 0,2ng/ml, positive hemocultures \< 48 hours, positive urine cultures, positive sputum cultures, any abnormalities identified by CT scan of brain-thorax and abdomino-pelvic region. * 17- Uncorrected thrombocytopenia or generalized coagulopathy (e.g., platelet count \< 100,000 / INR \> 2.0 in the absence of anticoagulation therapy). * 18- Hepatic insufficiency: a total bilirubin \> 3 mg/dL within 72 hours before implant, or biopsy proven liver cirrhosis or portal hypertension. * 19- Pulmonary vascular resistance (PVR) demonstrated to be unresponsive to pharmacological manipulation and the PVR \> 6 Wood units. * 20- Patients with a mechanical heart valve. * 21- Etiology of heart failure due to, or associated with, uncorrected thyroid disease, obstructive cardiomyopathy, pericardial disease, amyloidosis, active myocarditis, or restrictive cardiomyopathy, ventricular septal defect * 22- History of severe Chronic Obstructive Pulmonary Disease (COPD) or severe restrictive lung disease. GOLD (Global Initiative for Chronic Obstructive Lung Disease) score \< 3. * 23- Participation in any other study involving investigational drugs, devices, or biologics. * 24- Severe illness, other than heart disease, which would limit survival to a maximum of 1 year. * 25- Peripheral vascular disease with rest pain or ischemic ulcers of the extremities. * 26- Pregnancy. * 27- Patient unwilling or unable to comply with study requirements. * 28- Patients unable or unwilling to sign the written informed consent. * 29- Technical obstacles, which pose an inordinately high surgical risk, in the judgment of the investigator. * 30- Intolerance to anticoagulant or antiplatelet therapies or any other peri- or postoperative therapy that the investigator may administer based upon the patient's health status. * 31- Specific liver enzymes \[AST (SGOT) and ALT (SGPT)\] 3 times upper limit of normal within 72 hours before implant. * 32- Patient living alone (without an accompanying person). * 33- Rapid AF, unless nodo-hissian junction ablation is considered. * 34- Mid-septal end-systolic LV diameter ≤ 25mm * 35- Sequential Organ Failure Assessment Score (SOFA score \> 8) * 36- Minor subjects, persons deprived of liberty, protected adults, or those unable to consent * 37- Subjects who have participated in a clinical trial within 12 months * 38- Patient implanted with an Implantable Cardioverter Defibrillator (ICD) other than Medtronic and Boston.
Where it's running
-
Hospitalier IKEM
Prague, Czechia Recruiting -
Hôpital la pitié salpètrière
Paris, France Active not recruiting
Study contacts
- Study coordinator: Armand A ADJE, Clinical Project Manager
- Email: armand.adje@fine-heart.com
- Phone: +33640380538
Similar studies
Other studies for the same condition or treatment. Recruiting studies are listed first.
-
GDF-15 levels to predict early outcomes after LVAD implantation
We will see if pre-surgery blood levels of GDF-15 can predict early complications or death in adults having an LVAD implanted.
-
Tiered Palliative Care for Patients with Advanced Heart Failure or Cancer
This trial tests a home-based, tiered palliative care program to see if more personalized support improves symptoms and quality of life for adults with advanced heart failure or certain advanced cancers.
-
First-in-human CorWave LVAS for advanced heart failure
This trial will test a new CorWave left ventricular assist system (LVAS) in adults with advanced heart failure who are eligible for heart transplantation.
-
Understanding what to expect after getting a Ventricular Assist Device
This study is trying to help patients understand what to expect after getting a Ventricular Assist Device for heart failure, so they can feel more at ease and improve their quality of life.
-
Palliative care for patients with advanced heart failure or cancer
This study is testing a new palliative care program for people with advanced heart failure or cancer to see if it can improve their quality of life and reduce hospital visits compared to standard care.
-
Management of patients with advanced heart failure who may need a left ventricular assist device
This study tests how to best manage patients with advanced heart failure who might need a heart pump to see if personalized treatments can help them feel better and avoid surgery.
How to take part
- Review the eligibility criteria above with your treating physician.
- Check the official listing on ClinicalTrials.gov for the latest contact details and recruitment status.
- Contact the study coordinator or principal investigator to ask for pre-screening. Pre-screening is free and never obligates you to enroll.