Evaluating a new aortic endograft for treating thoracoabdominal aneurysms

Safety and Effectiveness of Physician-Modified Fenestrated and Branched Aortic Endografting for the Treatment of Thoracoabdominal and Pararenal Aortic Aneurysms

Not applicable Interventional Dartmouth-Hitchcock Medical Center · NCT06501872

This study is testing a new type of aortic stent to see if it’s a safer and more effective option for high-risk patients with thoracoabdominal aneurysms compared to traditional surgery.

Quick facts

PhaseNot applicable
Study typeInterventional
Enrollment80 (estimated)
Ages50 Years to 95 Years
SexAll
SponsorDartmouth-Hitchcock Medical Center Academic / other
Locations1 site (Lebanon, New Hampshire)
Trial IDNCT06501872 on ClinicalTrials.gov

What this trial studies

This study aims to assess the safety and effectiveness of a physician-modified fenestrated and branched aortic endograft in patients with thoracoabdominal aortic aneurysms (TAAAs). It is a prospective, two-arm feasibility study comparing the outcomes of this modified endograft to traditional open surgical repair methods. Eligible participants will be followed for five years post-procedure to evaluate long-term results and safety. The study focuses on patients who are considered high-risk for open surgery and meet specific size criteria for their aneurysms.

Who should consider this trial

Good fit: Ideal candidates are men and women aged 50 and older with thoracoabdominal aortic aneurysms that meet specific size and risk criteria for surgical intervention.

Not a fit: Patients with a life expectancy of less than two years unrelated to their aneurysm or those not meeting the size and risk criteria may not benefit from this study.

Why it matters

Potential benefit: If successful, this approach could provide a less invasive treatment option for patients with thoracoabdominal aortic aneurysms, potentially reducing recovery time and complications.

How similar studies have performed: Previous studies have shown promising results with similar endograft modifications, indicating potential for success in this approach.

Eligibility criteria

Show full inclusion / exclusion criteria
Main Arm Inclusion Criteria:

* Must be a man or woman 50 years of age or older by the date of informed consent
* Must have a thoracoabdominal aortic aneurysm of any Crawford classification (extent I-V) that extends no more proximal than the left subclavian artery.
* Must have an aneurysm size that meets standard indications for surgical repair (6.0 cm in maximum diameter in the descending thoracic aorta, or 5.5 cm in maximum diameter in the abdominal aorta)
* Must be considered, in the judgement of the Investigator, to be a high- risk candidate for open surgical repair
* Must commit to comply with the five-year study assessment schedule of events
* Must have a non-aneurysm-related life expectancy, in the judgement of the Investigator, of greater than 2 years

Expanded Selection Inclusion Criteria:

* Must be a man or woman 50 years of age or older by the date of informed consent
* Must have a thoracic, thoracoabdominal, or abdominal aortic aneurysm that necessitates coverage of one or more visceral vessels (celiac, superior mesenteric, or renals) for establishment of proximal and/or distal seal. The aneurysm must not extend proximal to the left subclavian artery, or, in the setting of more proximal disease, that disease must have been previously treated.
* Must have an aneurysm size that meets standard size indications for surgical repair (6.0 cm in maximum diameter in the descending thoracic aorta, or 5.5 cm in maximum diameter in the abdominal aorta); or, in the judgment of the Investigator, has aneurysm characteristics that portend a high risk of near-term rupture
* In the setting of an aortic dissection the following criteria must exist:

  * Access into the true lumen from the groin and at least one supra-aortic trunk vessel
  * A sealing zone in the target aorta (or surgical graft) that is proximal to the primary dissection, such that a stent graft would be anticipated to seal off the dissection lumen
  * A sealing zone in the target supra-aortic trunk vessels that is distal to the dissection, anticipated to seal off the dissection lumen, or surgically created
  * A true lumen size large enough to deploy the device and still gain access into the target branches
* Must be considered, in the judgement of the Investigator, to be a high-risk candidate for open surgical repair
* Patient must be able to provide informed consent
* Must commit to comply with the five-year study assessment schedule of events
* Must have a non-aneurysm-related life expectancy, in the judgement of the Investigator, of greater than 2 years

Main Arm Exclusion Criteria:

* Aneurysm due to acute or chronic dissection, intramural hematoma, penetrating aortic ulceration, pseudoaneurysm, mycotic aneurysm, or traumatic transection
* Ruptured or acutely symptomatic aortic aneurysm
* Known connective tissue disorder
* Imaging demonstrating any of the following:

  * Lack of 20 mm non-aneurysmal proximal seal zone (zone 3, or zone 2 with a carotid-subclavian bypass or transposition)
  * Lack of 15 mm non-aneurysmal distal seal zone(s) (aortic, common iliac, or external iliac)
  * Branch vessel target (renal, superior mesenteric, or celiac) \< 5 mm or \> 10 mm in average diameter
  * Untreated left subclavian artery stenosis or occlusion
  * Untreated unilateral or bilateral hypogastric artery occlusion
  * Signs that the inferior mesenteric artery is indispensable
  * Have branching, duplication, aneurysm, or untreatable stenosis of the celiac, superior mesenteric artery, or renal arteries that would preclude implantation of the investigational devices
* Known allergies to stainless steel, PTFE, polyester, polypropylene, nitinol, or gold
* History of anaphylaxis to contrast, with inability to prophylax appropriately.
* Have uncorrectable coagulopathy
* Have unstable angina
* Have a body habitus that would inhibit X-ray visualization of the aorta
* Have a major surgical or interventional procedure unrelated to the treatment of the aneurysm planned ≤30 days of the endovascular repair
* Known to be participating in any other clinical study which may affect performance of this - Ability to bear children
* Contraindication to oral antiplatelet therapy
* Prisoners or those on alternative sentencing
* Known systemic infection with potential for endovascular graft infection
* Anticipated need for MRI scanning within 3 months of insertion of investigational product
* Candidate for repair under the Instructions for Use of a commercially available, FDA-approved endovascular graft
* Can enroll in a manufacturer-sponsored clinical study at our institution or is willing and eligible to participate in a study with a manufacturer-made device at another institution.

Expanded Selection Exclusion Criteria:

* Known or suspected mycotic aneurysm
* Ruptured aneurysm with hemodynamic instability
* Known connective tissue disorder
* Imaging demonstrating any of the following:

  * Lack of 20 mm non-aneurysmal proximal seal zone (in either native aorta, elephant trunk graft, or aortic arch endograft)
  * Lack of 15 mm non-aneurysmal distal seal zone(s) (in either native aortoiliac vessels, prosthetic aortoiliac grafts, or aortoiliac endografts)
  * Branch vessel target (renal, superior mesenteric, or celiac) \> 10 mm in average diameter
* Known allergies to stainless steel, PTFE, polyester, polypropylene, nitinol, or gold
* History of anaphylaxis to contrast, with inability to prophylax appropriately.
* Have uncorrectable coagulopathy
* Have a body habitus that would inhibit X-ray visualization of the aorta
* Have a major surgical or interventional procedure unrelated to the treatment of the aneurysm planned ≤ 30 days of the endovascular repair
* Known to be participating in any other clinical study which may affect performance of this device
* Ability to bear children
* Contraindication to oral antiplatelet therapy
* Prisoners or those on alternative sentencing
* Known systemic infection with potential for endovascular graft infection
* Anticipated need for MRI scanning within 3 months of insertion of investigational product
* Candidate for repair under the Instructions for Use of a commercially available, FDA- approved endovascular graft
* Can enroll in a manufacturer-sponsored clinical study at our institution or is willing and eligible to participate in a study with a manufacturer-made device at another institution
* Other conditions or comorbidities that, in the opinion of the Investigator, would exclude the patient

Where this trial is running

Lebanon, New Hampshire

Study contacts

How to participate

  1. Review the eligibility criteria above with your treating physician.
  2. Visit the official trial page on ClinicalTrials.gov for the most current contact information and recruitment status.
  3. Contact the listed study coordinator or principal investigator to request pre-screening. Pre-screening is free and never obligates you to enroll.
Conditions Aortic Aneurysm
Last reviewed 2026-06-13 by the Find a Trial editorial team. Information on this page is for educational purposes and is not medical advice. Always consult qualified healthcare professionals about clinical trial participation.