CorVad Percutaneous Ventricular Assist System for Refractory Right Heart Failure
Official title: Safety and Feasibility of the CorVad Percutaneous Ventricular Assist System in Refractory Right Heart Failure
Run by Shenzhen Core Medical Technology CO.,LTD. · NCT07704424 · Data updated 2026-11-12
This trial tests whether the CorVad percutaneous ventricular assist device can be safely used to help patients with stubborn right heart failure when medicines and support devices aren’t enough.
Quick facts
| Study type | Interventional |
|---|---|
| Ages | 18 Years and up |
| Sex | All |
| Enrollment | 6 (estimated) |
| Sponsor | Shenzhen Core Medical Technology CO.,LTD. Industry-sponsored |
| Locations | 2 sites (Hefei, Anhui and 1 other locations) |
| Status | Recruiting |
| Started | June 2, 2026 |
| Main results expected | December 31, 2026 |
| Study ends | February 28, 2027 |
| Registry record updated | July 15, 2026 |
| Trial ID | NCT07704424 on ClinicalTrials.gov |
Is this trial a fit for you?
✓Likely a good fit
Adults with refractory right heart failure within 48 hours of LVAD implantation, myocardial infarction, heart transplantation, or open-heart surgery, who remain hemodynamically unstable despite maximal medical therapy.
✕Probably not a fit
Patients without refractory right heart failure or those who stabilize with medical therapy alone may not benefit from this device.
A plain-English reading of the study's rules. Only the study team can confirm whether you qualify.
What this trial studies
This interventional study assesses the safety and feasibility of the CorVad RS percutaneous ventricular assist system in patients who have refractory right heart failure after recent cardiac events or surgery and remain unstable despite optimized medical therapy. Eligible participants have right heart failure with low cardiac output and elevated central venous pressure despite high-dose inotropes or vasopressors. The trial focuses on device performance, technical feasibility, and immediate hemodynamic effects. No comparative or long-term efficacy endpoint is described in the provided materials. The study is conducted at multiple centers in China and is sponsored by Shenzhen Core Medical Technology Co., Ltd.
Why it matters
Potential benefit: If successful, patients may experience improved hemodynamics and stabilization of right-sided heart function while awaiting further treatment options.
How similar studies have gone: Prior experience with percutaneous ventricular assist devices in similar settings has shown feasibility but comes with risks; this study contributes initial safety and feasibility data for the CorVad RS.
Who can join: the full rules
Show full inclusion / exclusion criteria
Inclusion Criteria: 1. Patients who develop refractory right heart failure within 48 hours after left ventricular assist device (LVAD) implantation, myocardial infarction, heart transplantation, or open-heart surgery, defined as: * despite ongoing treatment with oral heart failure medications, including continuous infusion of high-dose inotropic agents and/or vasopressors, and/or the use of more than one inotropic agent and/or vasopressor, the cardiac index (CI) remains less than 2.2 L/min/m²; * and meets any one of the following criteria: 1) CVP \> 15 mmHg; or, 2) CVP/pulmonary capillary wedge pressure (PCWP) or CVP/left atrial pressure (LAP) \> 0.63; or, 3) echocardiographic evidence of moderate-to-severe right ventricular dysfunction meeting one of the following criteria: right ventricular basal diameter \> 42 mm, right ventricular short-axis (or mid-chamber) diameter \> 35 mm, tricuspid annular systolic excursion (TAPSE) score \< 14 mm, right ventricular fractional area change (FAC) \< 30%, tricuspid annular systolic peak velocity (TDI S') \< 9 cm/s, and right ventricular free wall longitudinal strain \> -20%. 2. ≥ 18 years old. 3. The patient or the patient's legal representative agrees to sign the informed consent form. Exclusion Criteria: 1. INTERMACS Stage 1 is defined as: despite the use of inotropic agents (positive inotropic drugs) and/or temporary mechanical support (such as IABP or ECMO), the patient remains hypotensive and shows signs of inadequate perfusion of vital organs (such as oliguria or worsening liver function), requiring immediate initiation of mechanical circulatory support to survive. 2. Severe hepatic or renal dysfunction, defined as total bilirubin ≥ 5 mg/dL or creatinine ≥ 4 mg/dL within 24 hours prior to treatment with the investigational device. 3. For patients who have undergone LVAD implantation, acute neurological injury occurring after implantation, including stroke, hypoxic encephalopathy, or acute neurological deficits (such as seizures or altered levels of consciousness). 4. Acute myocardial infarction with mechanical complications, including ventricular septal defect, cardiac rupture, or papillary muscle rupture. 5. Failed revascularization (for patients requiring right coronary revascularization), defined as a TIMI blood flow grade of 0 or 1 following percutaneous coronary intervention or coronary artery bypass grafting. 6. Active infection, meeting at least two of the following criteria: white blood cell count \> 12,500/μL, positive blood culture, or fever. 7. Thrombus in the right atrium, right ventricle, and/or pulmonary artery. 8. History of mechanical valve replacement of the tricuspid or pulmonary valve. 9. Severe tricuspid stenosis or regurgitation. 10. Severe pulmonary valve stenosis or regurgitation. 11. Severe pulmonary hypertension, defined as a pulmonary artery systolic pressure \> 60 mmHg. 12. Current diagnosis of pulmonary embolism. 13. History of pulmonary artery graft replacement (artificial vessel). 14. Current use of a right heart assist device or extracorporeal membrane oxygenation (ECMO) device. 15. Thrombosis of the internal jugular vein and deep veins of the lower extremities, and/or the presence of a vena cava filter. 16. Anatomical conditions that interfere with pump implantation or the safe use of the device, such as aortic dissection, Marfan syndrome, Erdheim-Chirlow disease (i.e., idiopathic medial necrosis, commonly associated with aortic dissection), etc. 17. Congenital heart disease that precludes device implantation, or an unrepairated atrial septal defect or patent foramen ovale. 18. Allergy or intolerance to contrast agents, or intolerance to anticoagulant or antiplatelet therapy. 19. History of thrombolytic therapy within the past 30 days, known coagulation disorders, or hematologic disorders causing blood cell fragility or hemolysis. 20. Female patients who are pregnant or breastfeeding. 21. Participation in any other clinical trial that may confound the study results or affect the study outcomes. 22. Other circumstances deemed by the investigator to be incompatible with inclusion in this study.
Where it's running
-
Beijing Anzhen Hospital, Capital Medical University
Beijing, Beijing Municipality, China Recruiting -
The First Affiliated Hospital of Anhui Medical University
Hefei, Anhui, China Not yet recruiting
Study contacts
- Study coordinator: Xiaoli Shi
- Email: shixiaoli@coretechmed.com
- Phone: +86 13418601356
Similar studies
Other studies for the same condition or treatment. Recruiting studies are listed first.
-
Right‑heart function and heart–lung interaction during ARDS with mechanical ventilation
This project will follow adults with ARDS on mechanical ventilation to see how positive‑pressure breathing affects the right heart over time and how that relates to circulation.
-
Cholate clearance testing for adults with Fontan circulation or right-sided heart failure
This trial will test whether the HepQuant dual cholate clearance blood test can measure liver function in adults with Fontan circulation or right-sided heart failure compared with healthy controls.
-
Feasibility assessment of treatments for right ventricular failure
This study is testing if adding two different medications to standard care can help people with right heart failure and pulmonary hypertension feel better and if it's possible to do a bigger study in the future.
-
Using valsartan to help treat pulmonary hypertension
This study is testing if the medication valsartan can help adults with pulmonary arterial hypertension feel better and improve their heart function.
-
Understanding the HeartMate 3 device and its impact on patients
This study looks at how the HeartMate 3 device affects patients with advanced heart failure by checking for problems like bleeding and infection, while also seeing how it impacts their quality of life.
-
Inhaled milrinone and epoprostenol before heart surgery to ease weaning from bypass
This trial tests whether inhaled milrinone and epoprostenol given before starting cardiopulmonary bypass can help people with right heart trouble during cardiac surgery.
How to take part
- Review the eligibility criteria above with your treating physician.
- Check the official listing on ClinicalTrials.gov for the latest contact details and recruitment status.
- Contact the study coordinator or principal investigator to ask for pre-screening. Pre-screening is free and never obligates you to enroll.